Transducer Open Loop for Measurement Hall Current Sensor

Product Details
Customization: Available
Type: Hall Type
Output Signal Type: Analog Output
Still deciding? Get samples of US$ 0/Piece
Request Sample
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Overseas Services
The supplier provides overseas services and supports countries including Korea, Turkey, Russia, Belarus, Uzbekistan, Kazakhstan, Indonesia, etc.

Overseas service content includes Debugging, Maintain, Repair, Training, Equipment Installation.
Full Customization
The supplier provides full customization services
Raw-Materials Traceability
The supplier has traceability identification of raw materials
to see all verified strength labels (26)
  • Transducer Open Loop for Measurement Hall Current Sensor
  • Transducer Open Loop for Measurement Hall Current Sensor
  • Transducer Open Loop for Measurement Hall Current Sensor
  • Transducer Open Loop for Measurement Hall Current Sensor
  • Transducer Open Loop for Measurement Hall Current Sensor
  • Transducer Open Loop for Measurement Hall Current Sensor
Find Similar Products
  • Overview
  • Principle
  • Feature
  • Advantages
  • Applications
  • Specification
  • Note
Overview

Basic Info.

Model NO.
CHK_E12S4
IP Rating
IP44
Certification
Ce, RoHS, ISO
Customized
Customized
Rated Input
50/100/200/300/400/600A
Measuring Range
0~+600A
Supply Voltage
DC +12 V
Output Voltage
+-4.0V
Offset Voltage
@IP=0, T=25c < +40 Mv
Power Consumption
15mA
Primary Through-Hole
D20.0mm
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
6000PCS/Month

Product Description

Principle
CHK_E12S4 series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage linearly related to the amplitude and phase of a magnetic field applied to it.
 
Feature
 * Open- loop
 * Supply voltage: DC +12V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.

 
Advantages
* Easy installation
* Can be customized
* No insertion losses
* Low power consumption
* Wide current measuring range
* High immunity to external interference

 
Applications
* Inverter applications
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS)
* Switched Mode Power Supplies (SMPS)
* Frequency drive control home appliances

 
Specification
Electrical data:(Ta=25ºC,Vc=+12.0VDC,RL=2Kilohm)
 

Parmeter
                                            Ref

 
CHK50
E12S4
CHK100
E12S4
CHK200
E12S4
CHK300
E12S4
CHK400
E12S4
CHK600
E12S4
Rated input  Ipn(A) 50 100 200 300 400 600
Measuring range  Ip(A) 0~+50 0~+100 0~+200 0~+300 0~+400 0~+600
Output voltage  Vo(V) ±4.000*(IP/IPN)
Output voltage  Vo(V) @IP=0,T=25°C                                                   0.000
Load resistance  RL(Kilohm) >2.0
Supply voltage  VC(V) +12.0 ±5%
Accuracy  XG(%) @IPN,T=25°C                                                       < ±1.0                   
Offset voltage  VOE(mV) @IP=0,T=25°C                                                     +40                            
Temperature variation of VOE  VOT(mV/°C) @IP=0,-40 +85°C                                           < ±1.0                                                     
  
Hysteresis offset voltage  VOH(mV) @IP=0,after  1*IPN                                             < ±20                                   
Linearity error  εr(%FS) < 1.0
Di/dt accurately followed(A/µs) > 100
Response time  tra(µs) @90% of IPN                                               < 3.0        
Power consumption  IC(mA) 15
Bandwidth  Bw(KHZ) @-3dBIPN                                                          DC-20          
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                                       3.0          
 
General data:
 Parameter Value
Operating temperature  TA(°C) -4+85
Storage temperature  TS(°C ) -55+125
Mass  M(g ) 70
Plastic material PBT G30/G15UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
 
Dimensions(mm):
CHK_E12S4M CHK_E12S4S Connection
Transducer Open Loop for Measurement Hall Current Sensor Transducer Open Loop for Measurement Hall Current Sensor
General tolerance
General tolerance:< ±0.5mm
Primary through-hole:D20.0±0.3
Connection of secondary : 
CHK_E12S4M: 
2510-04A (Instead of Molex 5045-04A)
CHK_E12S4S: 15EDGK3.81-04P
 
Note
* We provide FREE samples for your test!
  Purchase only when you are satisfied with the FREE samples.
Transducer Open Loop for Measurement Hall Current Sensor* Please let us know what kind of model, working voltage, input & output signals, mounting size.
* Or tell us your techincal requirement for the sensor selection.
* OEM/ODM is welcomed. 
  
CHEEMI TECHNOLOGY CO.,LIMITED.
Certification: ISO9001, CE, ROSH.
( Your reliable sensor-solution partner for Hall Current & Voltage Transducers, Proximity Switches/sensors, RTD Temperature Sensors, Current Transformers, Pressure Transmitter, Liquid Level Transmitter. )


Address: 3/F, Building 6, Jingang Science and Technology Innovation Park, No.1 Kechuang Road, Qixia District, Nanjing, China.
Post code: 210000


Web: current-sensor.en.made-in-china.com

Package 
* All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
* You can choose your own label(Screen Print or Laser Engraving).
* Can be netural packing or OEM.


Transducer Open Loop for Measurement Hall Current Sensor
Shipping 
* Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
* L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
* Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 


Warranty 
* We provide 1 year warranty.
* If the product is defective, please notify us within 3 days after receiving. 
* All products must be returned on their original condition, in order to qualify for a refund or exchange of goods.


Our Commitment 
Better Price than other suppliers for you because of Factory Direct Sale;
Better Quality than before caused by our 10+ years experience about sensors;
Fast Delivery made by our Enthusiasm;
Timing Reply in 24 hours all about our TEAM's Passion & Patience.
Transducer Open Loop for Measurement Hall Current Sensor
Transducer Open Loop for Measurement Hall Current Sensor
Transducer Open Loop for Measurement Hall Current Sensor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier