4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor

Product Details
Customization: Available
Voltage Type: DC+12.0V
Measuring Principle: Hall Type
Still deciding? Get samples of US$ 0/Piece
Request Sample
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • 4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
  • 4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
  • 4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
  • 4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
  • 4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
  • 4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
Find Similar Products
  • Overview
  • Advantages
  • Applications
  • Specification
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
CHV_AS12S4
Output Signal Type
Analog Type
Production Process
Integration
Material
Plastic
Accuracy Grade
0.5G
IP Rating
IP68
Certification
RoHS
Customized
Customized
Rated Input
05/10mA
Output Voltage
+4.0V
Installation
PCB Mounting
Free Samples
Available
Measuring Range
0~+20mA
Offset Voltage
@IP=0, T=25c < +40mv
Power Consumption
15mA
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
10000PCS/Month

Product Description

Advantages
 
4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
* Easy installation 
* Can be customized
High accuracy 
* Very good linearity

* Optimized response time, no insertion losses
* Low power consumption
Low temperature drift
* High immunity to external interference     
 
Applications
* Inverter applications
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS)
* Switched Mode Power Supplies (SMPS)
* Voltage detection of power distribution cabinet
 
* Battery power supply measurement
* Variable speed drive system
* Close loop feed-back control system application   

4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
Specification
Electrical data:(Ta=25ºC,Vc= ±15VDC)
 Parmeter
                                            Ref
CHV200 AC15D25 CHV400 AC15D25 CHV600 AC15D25 CHV800 AC15D25 CHV1000 AC15D25
Rated input voltage  Vpn(V) 200 400 600 800 1000
Measuring range  Vp(V) 0~±280 0~±360 0~±840 0~±1120 0~±1400
Turns ratio Np/NS (T) 1000 1000 1000 1000 1000
Secondary coil resistance RS (ohm) 60 60 60 60 60
Output current rms IS(mA) ±25*VP/VPN
Inside resistance RM (ohm) [(VC-3.0V)/(IS*0.001)]-RS
Supply voltage  VC(V) (±12~±15) ±5%
Accuracy  XG(%) @IPN,T=25°C                                                          < ±0.5                   
Offset current  IOE(mA) @IP=0,T=25°C                                                        < ±0.15                           
Temperature variation of IOE IOT(mA/°C) @IP=0,-40 ~ +85°C                                                 < ±0.5
Linearity error  εr(%FS)    < 0.2
Response time  tra(µs) @90% of IPN                                                           <40.0       
Power consumption  IC(mA)     15+Is
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                                                   2.5   
General data:
Operating temperature  TA(°C) -40 ~ +85
Storage temperature  TS(°C ) -55~ +125
Mass  M(g ) 50
Plastic material PBT G30/G15, UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
Dimensions(mm):

4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
Connection
4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
General tolerance
General tolerance:< ±0.2mm
size of Primary pin:
2pin,0.8*0.8±0.15mm;
Secondary 4pin:0.65*0.65±0.15mm
Instructions for use of the voltage sensor model CHV10AS12S4:
  1. Primary resistance R1: the sensor's optimum accuracy is obtained at the rated current. So R1 should be calculated so that the rated voltage to be measured corresponds to a primary current of 10mA.
  2. For example: Measuring rated voltage VPN=250V:
  1. R1=25K/2.5W,IP=10mA  Accuracy=±0.5% of VPN;  b) R1=50K/1.25W,IP=05mA  Accuracy=±1.0% of VPN;  
    Operating range(recommended):taking into the resistance of the primary windings(which must remain low compared to R1.in order to keep thermal deviation as low as possible) and the isolation,the sensor is suitable for measuring nominal voltage from 10 to 500V.

 
Company Profile

4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor

4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor
4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor

Packaging & Shipping
Package 
All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
You can choose your own label(Screen Print or Laser Engraving).
Can be netural packing or OEM.

Shipping
Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 
4.0V Output DC12V Closed Loop Hall Effect Voltage Transducer Sensor

 

FAQ

Q1:Can I get sample from you?
A:Yes,we can provide the free samples for your testing,please contact us for free and tell us which product you need.
Q2:Do you accept customization?
A:Yes,customization is acceptable,please contact our sales staffs for consult.
Q3:Can you provide help for technical issues?
A:Yes,we have more than 10 years of research and development in the electronic industry. If you need technical help in the purchase process, please feel free to contact us.
Q4 : Can I get a lower price if I order large quantities?
A : Yes,it's negotiable.
Q5: How about the quality guarantee period ?
A : Our warranty period is one year since from shipping date.
Q6: Can I add or delete items from my order if I change mind?
A : Yes, but you need to tell us asap, if your order has been done in our production line, we cannot change it.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier