High Precision Hall Current Transducer for BMS & PDU Systems

Product Details
Customization: Available
Type: Hall Type
Output Signal Type: Analog Output
Still deciding? Get samples of US$ 0/Piece
Request Sample
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • High Precision Hall Current Transducer for BMS & PDU Systems
  • High Precision Hall Current Transducer for BMS & PDU Systems
  • High Precision Hall Current Transducer for BMS & PDU Systems
  • High Precision Hall Current Transducer for BMS & PDU Systems
  • High Precision Hall Current Transducer for BMS & PDU Systems
  • High Precision Hall Current Transducer for BMS & PDU Systems
Find Similar Products
  • Overview
  • Principle
  • Advantages
  • Applications
  • Specification
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
CHK_LTK5S2 (HCS-LTK5)
Production Process
SemiConductor Integrated
Material
Mixture
Accuracy Grade
0.5G
Application
BMS, PDU
IP Rating
IP44
Certification
Ce, RoHS, ISO
Customized
Customized
Rated Input
100/200/300/600/800/900A
Measuring Range
0~+-900A
Supply Voltage
DC +5.0 V
Output Voltage
2.500+-2.0V
Offset Voltage
@IP=0, T=25c < +-25 Mv
Power Consumption
15mA
Primary Through-Hole
D20.0mm
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
6000PCS/Month

Product Description

Principle
CHK_LTK5S2 series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage linearly related to the amplitude and phase of a magnetic field applied to it.
  * Open- loop 
 * Supply voltage: DC +5.0V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.

 
High Precision Hall Current Transducer for BMS &amp; PDU Systems
High Precision Hall Current Transducer for BMS &amp; PDU Systems
High Precision Hall Current Transducer for BMS &amp; PDU Systems
Advantages
* Easy installation 
* Can be customized
* No insertion losses 
* Low power consumption
* Wide current measuring range 
* High immunity to external interference

 
Applications
* Inverter applications 
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS)  
* Switched Mode Power Supplies (SMPS)
* Frequency drive control home appliances
* BMS

PDU
High Precision Hall Current Transducer for BMS &amp; PDU Systems
Specification
Electrical data:(Ta=25ºC,Vc=+5.0VDC,RL=2Kilohm)
 Parmeter
                                            Ref
CHK100
LTK5S2
CHK200
LTK5S2
CHK300
LTK5S2
CHK600
LTK5S2
CHK800
LTK5S2
CHK900
LTK5S2
Rated input  Ipn(A) 100 200 300 600 800 900
Measuring range  Ip(A) 0~±100 0~±200 0~±300 0~±600 0~±800 0~±900
Output voltage  Vo(V) 2.500±2.0*(IP/IPN)
Output voltage  Vo(V) @IP=0,T=25°C                                                   2.500
Load resistance  RL(Kilohm) >2
Supply voltage  VC(V) +5.0 ±5%
Accuracy  XG(%) @IPN,T=25°C                                                    < ±1.0 
Offset voltage  VOE(mV) @IP=0,T=25°C                                                   ±25
Temperature variation of VOE  VOT(mV/°C) @IP=0,-40 +85°C                                           < ±1.0
Hysteresis offset voltageVOH(mV)  @IP=0,after  1*IPN                                            < ±20
Linearity error  εr(%FS) < 1.0
Di/dt accurately followed(A/µs) > 100
Response time  tra(µs) @90% of IPN                                                      < 3.0 
Power consumption  IC(mA) 15
Bandwidth  Bw(KHZ) @IPN                                                                 DC-20          
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                                            3.0          
General data:
 Parameter Value
Operating temperature  TA(°C) -4+85
Storage temperature  TS(°C ) -55+125
Mass  M(g ) 70
Plastic material PBT G30/G15UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
Dimensions(mm):
CHK_LTK5S2M CHK_LTK5S2S Connection
High Precision Hall Current Transducer for BMS &amp; PDU Systems High Precision Hall Current Transducer for BMS &amp; PDU Systems
General tolerance
General tolerance:< ±0.5mm
Primary through-hole:D20.0±0.3
Connection of Secondary :
CHK_LTK5S2M
2510-04A (Instead of Molex 5045-04A)
CHK_LTK5S2S15EDGK3.81-04P
 * We provide FREE samples for your test!
  Purchase only when you are satisfied with the FREE samples.
High Precision Hall Current Transducer for BMS &amp; PDU Systems* Please let us know what kind of model, working voltage, input & output signals, mounting size.
* Or tell us your techincal requirement for the sensor selection.
* OEM/ODM is welcomed. 
  


Company Profile
Cheemi Technology Co., Ltd specializes in development and commercialization of monitoring & measuring solution innovation, is a leading manufacturer of electrical sensors in china, with more than 80 workers, 2200m2 workshop, 20 years experience in current measurement. There are total 4 production lines, with an annual output of 8 million pieces. Its main products include hall effect current transducers, proximity switches, temperature sensors, current transformers, ISO, CE & RoSH certificated.
High Precision Hall Current Transducer for BMS &amp; PDU SystemsHigh Precision Hall Current Transducer for BMS &amp; PDU SystemsHigh Precision Hall Current Transducer for BMS &amp; PDU SystemsHigh Precision Hall Current Transducer for BMS &amp; PDU Systems
Packaging & Shipping
Package 
All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
You can choose your own label(Screen Print or Laser Engraving).
Can be netural packing or OEM.

Shipping
Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 
High Precision Hall Current Transducer for BMS &amp; PDU Systems

 

FAQ

Q1:Can I get sample from you?
A:Yes,we can provide the free samples for your testing,please contact us for free and tell us which product you need.
Q2:Do you accept customization?
A:Yes,customization is acceptable,please contact our sales staffs for consult.
Q3:Can you provide help for technical issues?
A:Yes,we have more than 10 years of research and development in the electronic industry. If you need technical help in the purchase process, please feel free to contact us.
Q4 : Can I get a lower price if I order large quantities?
A : Yes,it's negotiable.
Q5: How about the quality guarantee period ?
A : Our warranty period is one year since from shipping date.
Q6: Can I add or delete items from my order if I change mind?
A : Yes, but you need to tell us asap, if your order has been done in our production line, we cannot change it.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier