Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A

Product Details
Customization: Available
Type: Hall Type
Output Signal Type: Analog Output
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
  • Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
  • Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
  • Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
  • Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
  • Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Find Similar Products
  • Overview
  • Principle
  • Applications
  • Specification
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
CHK_BR5S2 series
Production Process
SemiConductor Integrated
Material
Mixture
Accuracy Grade
0.5G
Application
Switching Power Supply
IP Rating
IP44
Certification
CE, RoHS, ISO
Customized
Customized
Rated Input
50/100/200/300/400/600A
Measuring Range
0~+-600A
Supply Voltage
DC +5.0V
Output Voltage
2.500+-2.0V
Offset Voltage
@IP=0, T=25c < +-25mv
Power Consumption
15mA
Mounting
10.5*20.5mm
Plastic Material
PBT G30/G15, UL94-V0
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
5000PCS/Month

Product Description

Principle
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
CHK_BR5S2 series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage linearly related to the amplitude and phase of a magnetic field applied to it.
 * Open- loop 
 * Supply voltage: DC +5.0V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.


* Easy installation 
* Can be customized
* No insertion losses 
* Low power consumption
* Wide current measuring range 
* High immunity to external interference
Applications
* Inverter applications 
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS) 
* Switched Mode Power Supplies (SMPS)
* Frequency drive control home appliances
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
 
Specification
Electrical data:(Ta=25ºC,Vc=+5.0VDC,RL=2Kilohm)
 Parmeter
                                            Ref
CHK50BR5S2 CHK100BR5S2 CHK200BR5S2 CHK300BR5S2 CHK400BR5S2 CHK600BR5S2
Rated input  Ipn(A) 50 100 200 300 400 600
Measuring range  Ip(A) 0~±50 0~±100 0~±200 0~±300 0~±400 0~±600
Output voltage  Vo(V) 2.500±2.0*(IP/IPN)
Output voltage  Vo(V) @IP=0,T=25°C                                                                     2.500
Load resistance  Rl(Kilohm)  >2
Supply voltage  Vc(V) +5.0 ±5%
Accuracy  Xg(%) @IPN,T=25°C                                                                      < ±1.0
Offset voltage  Voe(mV) @IP=0,T=25°C                                                                     < ±25
Temperature variation of VOE  Vot(mV/°C) @IP=0,-40 +85°C                                                              < ±1.0
Hysteresis offset voltage  Voh(mV) @IP=0,after 1*IPN                                                                < ±20
Linearity error  εr(%FS) < 1.0
Di/dt accurately followed(A/µs) > 100
Response time  tra(µs) @90% of IPN                                                                        < 3.0        
Power consumption  Ic(mA)                                                                                                 15
Bandwidth  Bw(KHZ) @-3dB,IPN                                                                          DC-20          
Insulation voltage  Vd(Vd) @50/60Hz, 1min,AC                                                               2.5          
General data:
 Parameter Value
Operating temperature  Ta(ºC ) -4+85
Storage temperature  Ts(ºC ) -55+125
Mass  M(g ) 70
Plastic material PBT G30/G15,UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
Dimensions(mm):
 Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A Connection
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
General tolerance
General tolerance:< ±0.5mm
Primary through-hole:10.5*20.5±0.3
Connection of secondary : 
4 core cable length L=650mm;
Company Profile
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600AOpen-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
Packaging & Shipping
Package 
All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
You can choose your own label(Screen Print or Laser Engraving).
Can be netural packing or OEM.

Shipping
Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 
Open-Loop DC +5.0V Current Transducer Hall Effect Current Transducer Sensor 50/100/200/300/400/600A
 
FAQ

Q1:Can I get sample from you?
A:Yes,we can provide the free samples for your testing,please contact us for free and tell us which product you need.
Q2:Do you accept customization?
A:Yes,customization is acceptable,please contact our sales staffs for consult.
Q3:Can you provide help for technical issues?
A:Yes,we have more than 10 years of research and development in the electronic industry. If you need technical help in the purchase process, please feel free to contact us.
Q4 : Can I get a lower price if I order large quantities?
A : Yes,it's negotiable.
Q5: How about the quality guarantee period ?
A : Our warranty period is one year since from shipping date.
Q6: Can I add or delete items from my order if I change mind?
A : Yes, but you need to tell us asap, if your order has been done in our production line, we cannot change it.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier