• Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
  • Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
  • Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
  • Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
  • Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
  • Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor

Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor

Type: Hall Type
Output Signal Type: Analog Output
Production Process: SemiConductor Integrated
Material: Plastic
Accuracy Grade: 0.5G
Application: DC Panel, UPS, Charging Equipment
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Other
  • Overview
  • Feature
  • Advantages
  • Applications
  • Specification
  • Note
Overview

Basic Info.

Model NO.
CHB_E5S20
IP Rating
IP44
Certification
Ce, RoHS, ISO
Customized
Customized
Rated Input
50/100/150/200A
Measuring Range
0~+200A
Supply Voltage
DC +5.0V
Output Current
+20~100mA
Offset Current
@IP=0, T=25c < +0.2 Ma
Power Consumption
10mA
Primary Through-Hole
D20.5+-0.15mm
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
60000PCS/Year

Product Description

Feature
 * Closed- loop 
 * Supply voltage: DC +5.0V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Advantages
* Easy installation 
* Can be customized
High accuracy
*  Very good linearity

* No insertion losses 
* Low power consumption
* Wide current measuring range 
* High immunity to external interference
Low temperature drift
* Optimized response time, no insertion losses   
 
 
Applications
* Inverter applications
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS)
* Switched Mode Power Supplies (SMPS)
* Frequency drive control home appliances 

* Current detection in wind power industry
* Medical & coal mine quipment power supply measurement *DC/DC, AC/DC converter of hybrid electric vehicle

 
Specification
Electrical data:(Ta=25ºC,Vc=+5.0VDC)
 

Parmeter
                                            Ref

 
CHB50E5S20 CHB100E5S20 CH150E5S20 CHB200E5S20
Rated input  Ipn(A) 50 100 150 200
Measuring range  Ip(A) 0~+50 0~+100 0~+150 0~+200
Turns ratio Np/NS (T) 1:2500 1:2000 1:3000 1:2000
Output current IS (mA) +20*(IP/IPN) +50*(IP/IPN) +50*(IP/IPN) +100*(IP/IPN)
Secondary coil resistance RS(ohm) 28 22 38 22
Inside resistance RM(ohm)       [(VC-1.5V)/(IS*0.001)]-RS
Supply voltage  VC(V) +5.0 ±5%
Accuracy  XG(%) @IPN,T=25°C                                            < ±0.5                   
Offset current  IOE(mA) @IP=0,T=25°C                                          +0.2                       
Temperature variation of IOE  IOT(mA/°C) @IP=0,-40 +85°C                                 < ±0.005                                                    
  
Linearity error  εr(%FS) 0.1
Di/dt accurately followed(A/µs) > 50
Response time  tra(µs) @90% of IPN                                               1.0        
Power consumption  IC(mA) 10+Is
Bandwidth  BW(KHZ) @IPN                                                          DC-DC         
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                                      3.0    
 
General data:
 Parameter Value
Operating temperature  TA(°C) -4+85
Storage temperature  TS(°C ) -55+125
Mass  M(g ) 70
Plastic material PBT G30/G15UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
 
Dimensions(mm):
CHB-E5S20M CHB-E5S20S Connection
Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
General tolerance
General tolerance:< ±0.5mm
Primary through-hole: D20.5±0.15
Connection of Secondary : 
CHK-E5S20M: 
2510-04A (Instead of Molex 5045-04A)
CHK-E5S20S: 2EDG5.08-04P
 
Note
* We provide FREE samples for your test!
  Purchase only when you are satisfied with the FREE samples.
  
Please contact us to apply FREE Trial NOW !!

* Please let us know what kind of model, working voltage, input & output signals, mounting size.
* Or tell us your techincal requirement for the sensor selection.
* OEM/ODM is welcomed. 
  
CHEEMI TECHNOLOGY CO.,LIMITED.
Certification: ISO9001, CE, ROSH.
( Your reliable sensor-solution partner for Hall Current & Voltage Transducers, Proximity Switches/sensors, RTD Temperature Sensors, Current Transformers, Pressure Transmitter, Liquid Level Transmitter. )


Address: 3/F, Building 6, Jingang Science and Technology Innovation Park, No.1 Kechuang Road, Qixia District, Nanjing, China.
Post code: 210000


Web: current-sensor.en.made-in-china.com

Package 
* All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
* You can choose your own label(Screen Print or Laser Engraving).
* Can be netural packing or OEM.


Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
Shipping 
* Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
* L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
* Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 


Warranty 
* We provide 1 year warranty.
* If the product is defective, please notify us within 3 days after receiving. 
* All products must be returned on their original condition, in order to qualify for a refund or exchange of goods.


Our Commitment 
* Better Price than other suppliers for you because of Factory Direct Sale;
* Better Quality than before caused by our 10+ years experience about sensors;
* Fast Delivery made by our Enthusiasm;
* Timing Reply in 24 hours all about our TEAM's Passion & Patience.
Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor
Closed Loop Measuring Charging Equipment Power Supply Hall Current Sensor

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Other
Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001