• Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use
  • Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use
  • Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use
  • Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use

Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use

Type: Hall Type
Output Signal Type: Analog Output
Production Process: SemiConductor Integrated
Material: Mixture
Accuracy Grade: 1.0G
Application: PV
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Other
  • Overview
  • Principle
  • Feature
  • Advantages
  • Applications
  • Specification
  • Note
Overview

Basic Info.

Model NO.
CHK50LSR5S8
IP Rating
IP44
Certification
CE, RoHS, ISO
Customized
Customized
Rated Input
6/15/20/25/50A/60A
Measuring Range
0~±150A
Supply Voltage
DC +5.0V
Output Voltage
2.5V+-0.8V
Offset Voltage
@IP=0, T=25c < ±20mv
Power Consumption
15mA
Mounting
PCB
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Specification
12(g)
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
5000PCS/Month

Product Description

Principle

 

CHK-LSR5S8 series current transducer is a fully integrated linear Hall-effect current
sensor. Internal circuit adopts ASIC packaging technology products, which is debugged by software. Horizontally-mounted sensor makes space saving possible for the application.
 
Feature
 * Open- loop
 * Supply voltage: DC +5.0V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.

 
Advantages
Excellent accuracy
Very good linearity  
*  Low temperature drift
High immunity to external interference
*  Optimized response time, no insertion losses 
 
Applications
  Photovoltaic (pv) current applications 
 AC/DC variable-speed drive 

Switched Mode Power Supplies (SMPS) 
Uninterruptible Power Supplies (UPS)
 
 The  applications of inverter
 
Specification
Electrical data:(Ta=25ºC,Vc=+5.0VDC, RL=10, CL=10nF)
 
Parmeter
                                              Ref
CHK06LSR5S8 CHK10LSR5S8 CHK16LSR5S8 CHK20LSR5S8 CHK25LSR5S8 CHK32LSR5S8 CHK40LSR5S8 CHK50LSR5S8 CHK60LSR5S8
Rated input  Ipn(A) 06 10 16 20 25 32 40 50 60
Measuring range  Ip(A) ±15 ±25 ±37.5 ±50 ±62.5 ±80 ±100 ±125 ±150
Output voltage  Vo(V) 2.500±0.8*(IP/IPN)
Reference voltage  Vo(V) @IP=0,T=25°C                   2.500
Output resister RM(Ω) ≤20
Supply voltage  VC(V) +5.0 ±5%
Size of primary pins (mm)
  • 6.28*1.0
Vrefinternal resist RM(Ω)                                  200
Vref external range  (V) 2.0-2.8(Input)
Total accuracy  XG(%) @IPN,T=25°C                     < ±1.5                
Offset drift  mV/ºC @ -40~+105ºC                    ≤±0.1                      
Output drift  (mV/°C) @ -40~+105ºC                    ≤±0.1                                                
Linearity error  εr(%FS) < 0.5
Di/dt accurately followed(A/µs) > 50
Response time  tra(µs) @90% of IPN                      < 2.5       
Power consumption  IC(mA) 15+Is
Bandwidth  BW(KHZ) @-1dB,IPN                        DC-100          
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                 3.0    
General data:
 Parameter Value
Operating temperature  TA(°C) -40 ~ 105
Storage temperature  TS(°C ) -40~ +125
Mass  M(g ) 12
Plastic material PBT G30/G15, UL94- V0;
Standards IEC60950-1:2001
  EN50178:1998
  SJ20790-2000
  
Dimensions(mm):
Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use
 
 
Note
* We provide FREE samples for your test!
  Purchase only when you are satisfied with the FREE samples.
  
Please contact us to apply FREE Trial NOW !!

* Please let us know what kind of model, working voltage, input & output signals, mounting size.
* Or tell us your techincal requirement for the sensor selection.
* OEM/ODM is welcomed. 
  
CHEEMI TECHNOLOGY CO.,LIMITED.
Certification: ISO9001, CE, ROSH.
( Your reliable sensor-solution partner for Hall Current & Voltage Transducers, Proximity Switches/sensors, RTD Temperature Sensors, Current Transformers, Pressure Transmitter, Liquid Level Transmitter. )

Address: 22 Building, XianlongWan, Xianyin South Road, Qixia District, Nanjing City, Jiangsu Province, China.
Post code: 210000
 
 
Web: current-sensor.en.made-in-china.com


Package 
* All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
* You can choose your own label(Screen Print or Laser Engraving).
* Can be netural packing or OEM.


Open Loop Current Sensor 6-60A Current Monitoring Photovoltaic Inverter Use
Shipping 
* Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
* L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
* Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 


Warranty 
* We provide 1 year warranty.
* If the product is defective, please notify us within 3 days after receiving. 
* All products must be returned on their original condition, in order to qualify for a refund or exchange of goods.


Our Commitment 
Better Price than other suppliers for you because of Factory Direct Sale;
Better Quality than before caused by our 10+ years experience about sensors;
Fast Delivery made by our Enthusiasm;
Timing Reply in 24 hours all about our TEAM's Passion & Patience.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Other
Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001