• Current Transducer Hall Current Sensor Open Loop DC 3.3V
  • Current Transducer Hall Current Sensor Open Loop DC 3.3V
  • Current Transducer Hall Current Sensor Open Loop DC 3.3V
  • Current Transducer Hall Current Sensor Open Loop DC 3.3V

Current Transducer Hall Current Sensor Open Loop DC 3.3V

Type: Hall Type
Output Signal Type: Analog Output
Production Process: SemiConductor Integrated
Material: Mixture
Accuracy Grade: 0.5G
Application: Switching Power Supply
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Other
  • Overview
  • Principle
  • Feature
  • Advantages
  • Applications
  • Specification
  • Note
Overview

Basic Info.

Model NO.
CHK_BS3S1
IP Rating
IP44
Certification
CE, RoHS, ISO
Customized
Customized
Rated Input
50/100/200/300/400/600A
Measuring Range
0~+-600A
Supply Voltage
DC +3.3V
Output Voltage
1.650+-1.250V
Offset Voltage
@IP=0, T=25c < +-25mv
Power Consumption
15mA
Mounting
10.5*20.5mm
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
5000PCS/Month

Product Description

Principle
CHK_BS3S1 series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage linearly related to the amplitude and phase of a magnetic field applied to it.
 
Feature
 * Open- loop 
 * Supply voltage: DC +3.3V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.

 
Advantages
* Easy installation 
* Can be customized
* No insertion losses 
* Low power consumption
* Wide current measuring range 
* High immunity to external interference

 
Applications
* Inverter applications 
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS) 
* Switched Mode Power Supplies (SMPS)
* Frequency drive control home appliances

 
Specification
Electrical data:(Ta=25ºC,Vc=+3.3VDC,RL=2Kilohm)
 

Parmeter
                                            Ref

 
CHK50
BS3S1
CHK100
BS3S1
CHK200
BS3S1
CHK300
BS3S1
CHK400BS3S1 CHK600
BS3S1
Rated input  Ipn(A) 50 100 200 300 400 600
Measuring range  Ip(A) 0~±50 0~±100 0~±200 0~±300 0~±400 0~±600
Output voltage  Vo(V) 1.650±1.250*(IP/IPN)
Output voltage  Vo(V) @IP=0,T=25°C                   1.6500
Load resistance  RL(Kilohm) >2.0
Supply voltage  VC(V)                                +3.3 ±5%
Accuracy  XG(%) @IPN,T=25°C                   < ±1.0                   
Offset voltage  VOE(mV) @IP=0,T=25°C                  ±25                            
Temperature variation of VOE  VOT(mV/°C) @IP=0,-40 +85°C               < ±1.0                                                     
  
Hysteresis offset voltage  VOH(mV) @IP=0,after  1*IPN               < ±10                                   
Linearity error  εr(%FS) < 1.0
Di/dt accurately followed(A/µs) > 100
Response time  tra(µs) @90% of IPN                     < 3.0        
Power consumption  IC(mA) 15
Bandwidth  Bw(KHZ) @-3dBIPN                      DC-20          
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                2.5          
 
General data:
 Parameter Value
Operating temperature  TA(°C) -4+85
Storage temperature  TS(°C ) -55+125
Mass  M(g ) 70
Plastic material PBT G30/G15UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
 
Dimensions(mm):
CHK-BS3S1U CHK-BS3S1M Connection
Current Transducer Hall Current Sensor Open Loop DC 3.3V Current Transducer Hall Current Sensor Open Loop DC 3.3V
General tolerance
General tolerance:< ±0.5mm
Primary through-hole:10.5*20.5±0.3
Connection of secondary : 
2510-04A (instead of the Molex 5045-04A)
 
Note
* We provide FREE samples for your test!
  Purchase only when you are satisfied with the FREE samples.
  
Please contact us to apply FREE Trial NOW !!

* Please let us know what kind of model, working voltage, input & output signals, mounting size.
* Or tell us your techincal requirement for the sensor selection.
* OEM/ODM is welcomed. 
  
CHEEMI TECHNOLOGY CO.,LIMITED.
Certification: ISO9001, CE, ROSH.
( Your reliable sensor-solution partner for Hall Current & Voltage Transducers, Proximity Switches/sensors, RTD Temperature Sensors, Current Transformers, Pressure Transmitter, Liquid Level Transmitter. )

Address: 22 Building, XianlongWan, Xianyin South Road, Qixia District, Nanjing City, Jiangsu Province, China.
Post code: 210000
 
 
Web: current-sensor.en.made-in-china.com


Package 
* All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
* You can choose your own label(Screen Print or Laser Engraving).
* Can be netural packing or OEM.


Current Transducer Hall Current Sensor Open Loop DC 3.3V
Shipping 
* Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
* L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
* Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 


Warranty 
* We provide 1 year warranty.
* If the product is defective, please notify us within 3 days after receiving. 
* All products must be returned on their original condition, in order to qualify for a refund or exchange of goods.


Our Commitment 
Better Price than other suppliers for you because of Factory Direct Sale;
Better Quality than before caused by our 10+ years experience about sensors;
Fast Delivery made by our Enthusiasm;
Timing Reply in 24 hours all about our TEAM's Passion & Patience.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory, Other
Plant Area
>2000 square meters
Management System Certification
ISO 9001, ISO 14001