Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A

Product Details
Customization: Available
Type: Hall Type
Output Signal Type: Analog Output
Still deciding? Get samples of $ !
Request Sample
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

  • Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
  • Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
  • Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
  • Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
  • Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
  • Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
Find Similar Products
  • Overview
  • Principle
  • Applications
  • Specification
  • Company Profile
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
CHK_BS5S1
Production Process
SemiConductor Integrated
Material
Mixture
Accuracy Grade
0.5G
Application
Switching Power Supply
IP Rating
IP44
Certification
CE, RoHS, ISO
Customized
Customized
Rated Input
50/100/200/300/400/600A
Measuring Range
0~+-900A
Supply Voltage
DC +5.0V
Output Voltage
2.500+-1.0V
Offset Voltage
@IP=0, T=25c < +-25mv
Power Consumption
15mA
Mounting
10.5*20.5mm
Plastic Material
PBT G30/G15, UL94-V0
Transport Package
Standard Export Carton
Trademark
Cheemi
Origin
China(Mainland)
HS Code
90330000
Production Capacity
6000PCS/Month

Product Description

Principle
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
CHK_BS5S1 series Hall Effect Open Loop Current Sensor is a current measurement device which develops on base of the hall effect principle, wherein a Hall-effect device (HED) produces an output voltage linearly related to the amplitude and phase of a magnetic field applied to it.
 * Open- loop 
 * Supply voltage: DC +5.0V
 * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Applications
* Inverter applications 
* AC/DC variable-speed drive 
* Uninterruptible Power Supplies (UPS) 
* Switched Mode Power Supplies (SMPS)
* Frequency drive control home appliances
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
Specification
Electrical data:(Ta=25ºC,Vc=+5.0VDC,RL=2Kilohm)
 Parmeter
                                            Ref
CHK50
BS5S1
CHK100
BS5S1
CHK200
BS5S1
CHK300
BS5S1
CHK400
B
S5S1
CHK600
BS5S1
Rated input  Ipn(A) 50 100 200 300 400 600
Measuring range  Ip(A) 0~±100 0~±200 0~±400 0~±600 0~±800 0~±900
Output voltage  Vo(V) 2.500±1.0*(IP/IPN)
Output voltage  Vo(V) @IP=0,T=25°C                                                 2.500
Load resistance  RL(Kilohm) >2.0
Supply voltage  VC(V) +5.0 ±5%
Accuracy  XG(%) @IPN,T=25°C                                                 < ±1.0
Offset voltage  VOE(mV) @IP=0,T=25°C                                                ±25
Temperature variation of VOE  VOT(mV/°C) @IP=0,-40 +85°C                                         < ±1.0
Hysteresis offset voltage  VOH(mV) @IP=0,after  1*IPN                                          < ±20
Linearity error  εr(%FS) < 1.0
Di/dt accurately followed(A/µs)  > 100
Response time  tra(µs) @90% of IPN                                                    < 3.0        
Power consumption  IC(mA) 15
Bandwidth  Bw(KHZ) @-3dBIPN                                                      DC-20          
Insulation voltage  Vd(KV) @50/60Hz, 1min,AC                                            2.5          
General data:
 Parameter Value
Operating temperature  TA(°C) -4+85
Storage temperature  TS(°C ) -55+125
Mass  M(g ) 70
Plastic material PBT G30/G15UL94- V0;
Standards IEC60950-1:2001
EN50178:1998
SJ20790-2000
Dimensions(mm):
CHK_BS5S1U           CHK_BS5S1M Connection
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
General tolerance
General tolerance:< ±0.5mm
Primary through-hole:10.5*20.5±0.3
Connection of secondary : 
2510-04A (instead of the Molex 5045-04A)
Company Profile
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600AOpen Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600AOpen Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600AOpen Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
Packaging & Shipping
Package 
All our sensors will be well packed with bubble & carton. (Bubble packing→4 small carton→1 big carton)
You can choose your own label(Screen Print or Laser Engraving).
Can be netural packing or OEM.

Shipping
Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 
Open Loop DC 5V Current Transducer Hall Current Sensor 50/100/200/300/400/600A
FAQ

Q1:Can I get sample from you?
A:Yes,we can provide the free samples for your testing,please contact us for free and tell us which product you need.
Q2:Do you accept customization?
A:Yes,customization is acceptable,please contact our sales staffs for consult.
Q3:Can you provide help for technical issues?
A:Yes,we have more than 10 years of research and development in the electronic industry. If you need technical help in the purchase process, please feel free to contact us.
Q4 : Can I get a lower price if I order large quantities?
A : Yes,it's negotiable.
Q5: How about the quality guarantee period ?
A : Our warranty period is one year since from shipping date.
Q6: Can I add or delete items from my order if I change mind?
A : Yes, but you need to tell us asap, if your order has been done in our production line, we cannot change it.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier